Instructions of fusion splicer up and down in the collecting process

Instructions of fusion splicer up and down in the collecting process

The main reason why fusion splicer up and down in the collecting process is the V-slot position is offset. Followed by the problem caused by fiber presser foot.

The above solution to the problem:

1> Press the “Reset” key to reset the system.

2> check the bare fiber is clean, if not clean, then deal with it.fusion splicer kl 360E

3> Check the Y / Z fiber end position deviation is less than 0.5 mm, if less than then the following operation, or sent to the factory repair.

4> Clean the dust deposited in the V-groove of the splicer.

5> Press the small pressure head with finger to determine whether the small pressure head compaction fiber, if not compaction is handled. If it is still not handled properly, please contact the maintenance company.