Optical fusion splicer internal lithium battery

Optical fusion splicer internal lithium battery

1. After the battery is placed for a long time, it is easy to enter the dormant state. At this time, the capacity is lower than the normal value. The time of use is shortened, but only after 2 ~ 3 normal charge and discharge cycles can activate the battery and return to normal capacity. Lithium battery almost no memory effect, can be charged at any time.

2. Lithium battery self-discharge phenomenon, if the battery for a long time low pressure preservation, may be due to self-discharge and damage the internal structure of the battery to reduce battery life. So long-term preservation of the lithium battery should be charged every 3 to 6 months, pay attention to the battery capacity of 60% to 80% can not be filled.

3. Long-term storage of the battery (storage time of more than 6 months) when the temperature range: 0 ℃ ~ 40 ℃. Battery temperature (storage time is less than or equal to 6 months) when the temperature range: -20 ℃ ~ 60 ℃.

4. To ensure the safety of charging, fusion splicer internal lithium battery charging temperature range of 0 ℃ ~ 40 ℃. When the ambient temperature exceeds this range, charging will automatically terminate.